Decon Infratech · Since 1986

    Fire Hydrant and Automatic Sprinkler System Contractor

    Design, supply, installation, testing and commissioning for commercial, industrial and institutional projects.

    • Internal, external and yard hydrant systems
    • Automatic sprinkler networks with alarm valves and flow switches
    • Integration with fire pumps, storage and detection
    • Testing, commissioning and Fire NOC assistance where in scope

    Decon Infratech is a specialist fire hydrant and automatic sprinkler system contractor for commercial, industrial and institutional projects. We take up complete system execution — from design coordination and material supply through to installation, hydro-testing, commissioning and handover.

    Individual equipment sales are handled separately; this page is for clients planning a full hydrant or sprinkler system on a live project.

    Fire Hydrant Systems

    A fire hydrant system is a manually-operated water-based system that delivers pressurised water at strategic points around a building or site for use by trained personnel or the fire brigade.

    Typical Components

    • Internal hydrants
    • External / yard hydrants
    • Wet risers
    • Hose reels
    • Landing valves
    • Fire-service inlet connections
    • Hydrant piping and accessories

    Automatic Sprinkler Systems

    An automatic sprinkler system delivers water automatically at the seat of a fire through heat-activated sprinkler heads on a pressurised piping network.

    Typical Components

    • Sprinkler piping networks
    • Sprinkler heads
    • Alarm valves
    • Flow switches
    • Test and drain arrangements
    • Zoning and integration with fire pumps and alarms

    Hydrant vs Sprinkler — At a Glance

    The two systems are complementary, not alternatives. Most codes and typical building occupancies require both, integrated with a common pump room and water source.

    AspectFire Hydrant SystemAutomatic Sprinkler System
    ActivationManual — opened by trained personnel or fire brigadeAutomatic — heat-activated sprinkler head opens
    Primary FunctionBulk water delivery at strategic points around the buildingRapid, localised control at the seat of the fire
    Typical OperationLanding valve opened, hose deployed, water directed by operatorOnly sprinklers near the fire operate; alarm valve trips
    Main EquipmentLanding valves, hose reels, hoses, hydrants, pipingSprinklers, alarm valves, flow switches, sprinkler piping
    Role in Integrated SystemStandby response capability for personnel and fire servicesFirst-line automatic response for early fire control

    System Integration

    Neither system works in isolation. In a building fire-protection installation, the fire-water storage, pump room, hydrant network, sprinkler network and fire-alarm system are engineered as one integrated whole.

    Fire-water storage feeds the pump room. Fire pumps pressurise a common riser network. That network branches into the hydrant and sprinkler distributions. Flow switches and alarm valves on the sprinkler side tie back to the fire-alarm system so that any operation is annunciated. Testing and commissioning verify the behaviour of the full chain — not just individual components.

    Decon’s Scope of Work

    Project Delivery

    • Design coordination with the fire consultant and PMC
    • BOQ and specification review
    • Material supply against approved makes
    • Piping installation — hydrant and sprinkler networks
    • Equipment installation — valves, pumps, panels and accessories
    • Hydro-testing and system testing
    • Commissioning and performance verification
    • Handover documentation and site support
    • Fire NOC assistance — where included in Decon’s scope

    Common Project Problems (and What to Watch For)

    Issues that we regularly see brought to us on struggling projects — worth flagging early on any hydrant or sprinkler installation.

    Typical Issues

    • Poor system coordination between fire, MEP and structural teams
    • Incorrect zoning of sprinkler networks
    • Inaccessible valves and test connections
    • Incomplete or undocumented testing
    • Improper pipe supports and hangers
    • Pump-room integration issues — power, controls, headers
    • Lack of maintenance access around key equipment
    • Executed layout mismatched against approved drawings

    Project Applications

    Commercial Buildings
    Factories
    Warehouses
    Hospitals
    Schools & Institutions
    Offices
    Hotels
    Infrastructure Facilities

    Hydrant and Sprinkler Installation — Okhla Phase-1 Reference

    Photographs from Decon’s completed 1,00,000 sq. ft. commercial fire-fighting project in Okhla Industrial Area Phase-1, New Delhi, showing hydrant piping, sprinkler coverage, hose reels and pump-room equipment on a live project.

    View the full Okhla Phase-1 case study →
    External hydrant header with landing valve and hose cabinet installed by Decon Infratech at the Okhla Phase-1 project
    External hydrant header with landing valve and hose cabinet
    Warehouse floor overhead sprinkler coverage installed by Decon Infratech at the Okhla Phase-1 project
    Warehouse floor — overhead sprinkler coverage
    Overhead hydrant piping network across warehouse bays at the Okhla Phase-1 project by Decon Infratech
    Overhead hydrant piping across warehouse bays
    Fire pump room with diesel-engine driven fire pump and headers at the Okhla Phase-1 project by Decon Infratech
    Fire pump room — diesel-engine driven pump with headers
    Internal hose reel cabinet with landing valve and pressure gauge installed at the Okhla Phase-1 project by Decon Infratech
    Internal hose reel cabinet with landing valve
    Vertical riser with pressure gauge and alarm arrangement installed at the Okhla Phase-1 project by Decon Infratech
    Vertical riser with pressure gauge and alarm arrangement

    Frequently Asked Questions

    Most commercial and industrial occupancies require both, integrated together. The exact requirement is driven by the applicable code, the building’s occupancy, its size and the approved fire scheme for the project.

    Discuss Your Hydrant or Sprinkler Project

    Share the project location, type and approximate size. A Decon engineer will respond within one working day.

    WhatsApp Us
    Decon Infratech

    Decon Infratech Engineering Private Limited

    CIN: U43299DL2026PTC469716

    MEP | Fire Fighting | Sewage Treatment Plant | Water Treatment Plant

    View Corporate Registration

    © 2026 Decon Infratech Engineering Private Limited. All Rights Reserved. | www.deconindia.in